Breaking News:
Programat EP 3010/G2 110-120V/50-60Hz -- " The Programat G2 Furnaces have a modern design, intuitive operation and a ..." -- 17 April 2022
Programat EP 5010/G2 110-120V/50-60Hz -- " The Programat G2 Furnaces have a modern design, intuitive operation and a high ..." -- 17 April 2022
Programat P510/G2 110-120V/50-60Hz -- " The Programat G2 Furnaces have a modern design, intuitive operation and a high ..." -- 17 April 2022
Programat P710 -- " The Programat® P710 leads ceramic furnaces into the future with its unique cutting ..." -- 05 October 2015
Programat P710/G2 110-120V/50-60Hz -- "   The Programat G2 Furnaces have a modern design, intuitive operation and a ..." -- 17 April 2022
The Programat G2 Furnaces have a modern design, »
The Programat G2 Furnaces have a modern design, »
  The Programat G2 Furnaces have a modern »
The Programat G2 Furnaces have a modern design, »
The Programat® P710 leads ceramic furnaces into the »
2560254
Today
Yesterday
This Week
Last Week
This Month
Last Month
All days
237
847
2879
2212601
20436
16786
2560254

Your IP: 162.158.78.238
2024-04-25 08:12

free counters

 

Trifecta Medals
TRIFECTA Archwire logo
The Right Force on the Right Teeth at the Right Time

Compare to BioForce® by GAC

 
TRIFECTA Force Chart
 
Anterior Region = Gentle Forces
The incisor segment has the lowest heat-activated force level specific to moving small, single rooted teeth. The archwire provides gentle forces for patient comfort, reduces unnecessary tooth pressure and decreases the possibility of root resorption.
Bicuspid Region = Moderate Forces
This segment of the archwire delivers a slightly increased force level for moving the larger bicuspids or premolars. The progressively increased force provides quick leveling and alignment to speed up treatment time, without compromising patient comfort levels.
Molar Region = Heavy Forces
The posterior segment of the archwire generates the most force in order to align the larger, more difficult to move first and second molars. Regular archwires have only one force level throughout, which would require 2 or 3 wire changes to achieve the same movement you can get with 1 Trifecta wire.
TRIFECTA Force Levels in Grams
Wire Size Anterior Bicuspid Molar
.016" 50 65 95
.018" 65 85 120
       
.016" x .016" 65 85 120
.018" x .018" 80 110 155
.020" x .020" 100 150 215
.016" x .022" 105 155 220
.017" x .025" 120 195 275
.018" x .025" 140 200 290
.019" x .025" 155 210 300
       
Round Upper Lower
.016"
6003-016
6003-116
.018"
6003-018
6003-118
     
Rectangle Upper Lower

.016" x .016"

6003-041
6003-141
.018" x .018"
6003-047
6003-147
.020" x .020"
6003-049
6003-149
.016" x .022"
6003-042
6003-142
.017" x .025"
6003-044
6003-144
.018" x .025"
6003-046
6003-146
.019" x .025"
6003-048
6003-148
  • Prev
  • Our Valued Partners
Scroll to top